[1] 庞然,李琳琳,万霞,等.多层螺旋CT平扫及三维重建对老年复杂性髋关节骨折的评估效果[J].医疗装备, 2021, 34(24):14-15. [2] 牛延涛,张永县,卓维海,等.加强放射诊断辐射剂量管理的必要性及应对策略[J].中华放射医学与防护杂志, 2023, 43(4):241-247. [3] 朱慧杰,高富强,刘丰林. CT射线动态滤波器研究综述[J].仪器仪表学报, 2017, 38(3):643-652. [4] Paolicchi F, Bastiani L, Negri J, et al. Effect of CT localizer radiographs on radiation dose associated with automatic tube current modulation:A multivendor study[J]. Current Problems in Diagnostic Radiology, 2020, 49(1):34-41. [5] 韩林梅,俞琴.头颅CT偏中心定位对扫描图像质量的影响[J].临床放射学杂志, 2019, 38(12):2420-2424. [6] Singh S, Kalra M K, Deedar Gilman M, et al. Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT:A pilot study[J]. Radiology, 2011, 259(2):565-573. [7] Singh S, Kalra M K, Ali Khawaja R D, et al. Radiation dose optimization and thoracic computed tomography[J]. Radiologic Clinics of North America, 2014, 52(1):1-15. [8] Colvert B, Rigolli M, Craine A, et al. Heart-centered positioning and tailored beam-shaping filtration for reduced radiation dose in coronary artery calcium imaging:A Multi-Ethnic Study of Atherosclerosis (MESA) Study[J]. Medical Physics, 2021, 48(9):4966-4977. [9] 闫士举,王蕴衡,仇庆.非等中心锥束CT成像系统标定及三维重建[J].中国医学影像技术, 2014, 30(11):1739-1744. [10] 肖梦强,沈君,刘金丰,等.等中心扫描降低多层螺旋CT冠状动脉血管成像辐射剂量的随机对照研究[J].中华解剖与临床杂志, 2019, 24(2):145-150. [11] Euler A, Saltybaeva N, Alkadhi H. How patient off-centering impacts organ dose and image noise in pediatric head and thoracoabdominal CT[J].European Radiology, 2019, 29(12):6790-6793. [12] 刘保东,周玉汀,孙久波,等.自动管电流调节低剂量CT引导下经皮肺穿刺活检的应用观察[J].中华肿瘤防治杂志, 2021, 28(18):1405-1409. [13] Franck C, Bacher K. Influence of localizer and scan direction on the dose-reducing effect of automatic tube current modulation in computed tomography[J]. Radiation Protection Dosimetry, 2016, 169(1-4):136-142. [14] Moro L, Panizza D, D'Ambrosio D, et al. Considerations on an automatic computed tomography tube current modulation system[J]. Radiation Protection Dosimetry, 2013, 156(4):525-530. [15] Zheng X M, Gutsche L, Al-Hayek Y, et al. Impacts of phantom off-center positioning on CT numbers and dose index CTDIv:An evaluation of two CT scanners from GE[J]. Journal of Imaging, 2021, 7(11):235-247. [16] 刘丹丹,牛延涛.不同定位像在管电流自动调制技术CT扫描中对辐射剂量的影响[J].中华放射学杂志, 2017, 51(7):525-528. [17] Saltybaeva N, Krauss A, Alkadhi H. Effect of localizer radiography projection on organ dose at chest CT with automatic tube current modulation[J]. Radiology, 2017, 282(3):842-849. [18] Kaasalainen T, Mäkelä T, Kortesniemi M. The effect of vertical centering and scout direction on automatic tube voltage selection in chest CT:A preliminary phantom study on two different CT equipments[J]. European Journal of Radiology Open, 2018, 17(6):24-32. |