摘要: 卤化银感光材料面世已有一百余年的历史,其基本原材料之一的硝酸银的纯度,对感光材料的感光特性有着不容忽视的影响。国外各著名感光材料厂家对硝酸银中杂质的含量,都有严格的内控标准。但分析方法一般不公开发表。文献上偶见到少量工作[1-3],一般也非感光材料厂家的实用技术。

关键词: 痕量分析, 感光材料, 金, 硝酸银

Abstract: Trace gold in AgNO3 was separated from main element Ag with 2 mol/L HC1 as a precipitant.After filtering, Au3+ in the solution was extracted with 6ml 55% TBP-CHCl3 and was determined by graphite furnace atomic absorption spectrometry.The method is convenient and sensitive.The recovery and relative standard deviation are 95-105% and < 15%, respectively.