影像科学与光化学 ›› 2022, Vol. 40 ›› Issue (6): 1596-1601.DOI: 10.7517/issn.1674-0475.220811

• 综述与论文 • 上一篇    下一篇

DSCT联合miR-10b-3p在脑卒中颈动脉狭窄诊断中的应用

司延栋1, 陈昆涛1, 刘亮2, 彭兴慧2   

  1. 1. 遵义医科大学第五附属(珠海)医院放射科, 广东 珠海 519100;
    2. 广东省中医院斗门医院(珠海市斗门区侨立中医院)放射科, 广东 珠海 519125
  • 收稿日期:2022-08-08 出版日期:2022-11-23 发布日期:2022-11-15
  • 通讯作者: 陈昆涛

Application of Dual-source CT Combined with miR-10b-3p in the Diagnosis of Stroke Carotid Artery Stenosis

SI Yandong1, CHEN Kuntao1, LIU Liang2, PENG Xinghui2   

  1. 1. Department of Radiology, The Fifth Affiliated Hospital(Zhuhai) of Zunyi Medical University, Zhuhai 519100, Guangdong, P. R. China;
    2. Department of Radiology, Doumen Hospital, Guangdong Provincial Hospital of Chinese Medicine(Zhuhai Doumen District Qiaoli Hospital of Traditional Chinese Medicine), Zhuhai 519125, Guangdong, P. R. China
  • Received:2022-08-08 Online:2022-11-23 Published:2022-11-15

摘要: 本文探讨双源CT(DSCT)联合miR-10b-3p在缺血性脑卒中患者颈动脉狭窄诊断中的应用价值。选择133例确诊为急性缺血性脑卒中患者作为研究对象,所有患者均进行了DSCT检查,测量狭窄率和钙化情况。通过RT-qPCR检测患者血清miR-10b-3p水平。结果显示,DSCT诊断50%狭窄的AUC为0.995,敏感性为100.00%,特异性为94.20%。随着狭窄率的升高,血清miR-10b-3p水平呈逐渐降低的趋势(P<0.05)。与软斑块组和纤维斑块组比较,钙化斑块组患者的血清miR-10b-3p水平显著降低(P<0.05)。血清miR-10b-3p诊断钙化斑块的AUC为0.823。miR-10b-3p诊断50%颈动脉狭窄的AUC为0.815。DSCT联合miR-10b-3p诊断50%颈动脉狭窄的AUC、敏感性和特异性分别为0.995、100.00%和94.20%。DSCT对脑卒中患者颈动脉狭窄的诊断价值高,血清miR-10b-3p可作为DSCT检查颈动脉狭窄的辅助指标,可作为颈动脉斑块形成的生物标志物。

关键词: 缺血性脑卒中, 双源CT, 颈动脉狭窄, miR-10b-3p, 钙化斑块

Abstract: This article explored the application value of dual-source CT (DSCT) combined with miR-10b-3p in the diagnosis of carotid artery stenosis in patients with ischemic stroke. A total of 133 patients with confirmed acute ischemic stroke were selected as the research objects. All patients underwent DSCT examination, and the stenosis rate and calcification were measured. Serum miR-10b-3p levels of patients were detected by RT-qPCR. The results showed that the AUC of DSCT for diagnosing 50% stenosis was 0.995, the sensitivity was 100.00%, and the specificity was 94.20%. With the increase of stenosis rate, the level of serum miR-10b-3p decreased gradually (P<0.05). Compared with the soft plaque group and the fibrous plaque group, the serum miR-10b-3p level in the calcified plaque group was significantly lower (P<0.05). The AUC of serum miR-10b-3p for diagnosing calcified plaque was 0.823. The AUC of miR-10b-3p for the diagnosis of 50% carotid artery stenosis was 0.815. The AUC, sensitivity and specificity of DSCT combined with miR-10b-3p in the diagnosis of 50% carotid stenosis were 0.995, 100.00% and 94.20%, respectively. DSCT has high diagnostic value for carotid artery stenosis in patients with stroke. Serum miR-10b-3p can be used as an auxiliary index for DSCT to detect carotid artery stenosis and a biomarker for carotid plaque formation.

Key words: ischemic stroke, dual-source CT, carotid artery stenosis, miR-10b-3p, calcified plaque